← Current electricity

Class 12 Physics · 10 worked problems

Learn the method, then try ten fresh questions with automatic marking and explanations.

Take topic test →

Terminal voltage and internal resistance

Charge loses energy inside a discharging cell. Terminal voltage falls from the open-circuit emf by the internal voltage drop. V=E−IrV=E-Ir.

What you’ll be able to do

  • Distinguish emf from terminal voltage under load.
  • Infer emf and internal resistance from two measurements.
  • Check energy accounting and distinguish maximum load power from maximum efficiency.

Before you start: Ohm’s law, series resistance, Kirchhoff’s loop rule and P = VI. Treat the cell as constant emf E in series with a constant internal resistance r.

Where the energy per coulomb goes

Emf E is the energy supplied by the cell per unit charge in this circuit model. When a discharging cell supplies current I, internal resistance uses Ir volts of the loop budget. Terminal voltage across the external load is therefore V=E−IrV=E-Ir. A high-resistance voltmeter at open circuit draws negligible current, so it reads approximately E.

With an external resistor R, the same current passes through R and r. The loop equation E=IR+IrE=IR+Ir gives I=ER+rI=\frac{E}{R+r}. Terminal voltage is IR. Increasing R reduces current and the internal voltage drop, so terminal voltage rises towards E even though the load power eventually falls.

Read the axes before reading the slope

On a graph of terminal voltage V vertically against discharge current I horizontally, the intercept is E and the slope is −r. Resistance is positive; the negative slope describes a voltage decrease with increasing load current.

If the axes are reversed, I = E/r − V/r, so the slope is −1/r. Constant voltage offsets change the apparent intercept but cancel in differences; they do not change a slope calculated from correctly paired readings. This assumes the cell itself does not change temperature or state appreciably during measurement.

Power, efficiency and charging

The source supplies power EI. The load receives I2RI^{2}R and the internal resistor dissipates I2rI^{2}r; these sum to EI. The efficiency of energy delivery to a resistive load is RR+r\frac{R}{R+r}. High efficiency does not necessarily mean high power: an almost open circuit can be efficient in the limiting sense while delivering negligible power.

For a fixed E and positive r, load power E2R(R+r)2\frac{E^2R}{(R+r)^2} reaches its maximum at R = r. At that point half the supplied power heats the internal resistance, so efficiency is 50%. Do not use this operating condition as a design recommendation for a real battery.

When an external source drives current into the cell’s positive terminal, the terminal voltage in the idealised charging model is E + Ir. Reusing the discharge formula with an unsigned positive charging current gets the sign wrong. State the current convention before writing the loop equation.

r = 1 ΩR = 5 ΩE = 12 VIr = 2 VIR = 10 VDischarge current I = 2 A
In this discharge example, a 12 V emf supplies a 1 Ω internal resistance and a 5 Ω load in series. Current is 2 A; 10 V reaches the load and 2 V is dropped internally.

Rules and when they apply

V=E−IrI=ER+r\begin{gathered}V=E-Ir\\I=\frac{E}{R+r}\end{gathered}
Discharge current leaves the positive terminal; E, r and R are positive model constants.

An ohmic load and a cell whose emf and internal resistance remain approximately fixed.

r=−ΔVΔIE=V+Ir\begin{gathered}r=-\frac{\Delta V}{\Delta I}\\E=V+Ir\end{gathered}
Use two different discharge currents to remove the unknown intercept.

This slope formula assumes V is vertical and I is horizontal.

Pload=I2RPinternal=I2rη=RR+r\begin{gathered}P_{\mathrm{load}}=I^2R\\P_{\mathrm{internal}}=I^2r\\\eta=\frac{R}{R+r}\end{gathered}
Compare useful external power with source power EI.

For this series model; other chemical and thermal losses are not separately modelled.

Follow the reasoning

Worked example 1

Two readings reconstruct a cell

A cell’s terminal voltage is 5.7 V at 0.30 A and 5.1 V at 0.90 A while discharging. Find E and r.

Step-by-step explanation
  1. Write V=E−IrV=E-Ir for each point. Subtract to eliminate E: 5.7 − 5.1 = r(0.90 − 0.30).
  2. Thus r = 0.60 V / 0.60 A = 1.0 Ω. Substitute in either reading: E = 5.7 + 0.30 × 1.0.
  3. Check the second reading with the same constants: 6.0 − 0.90 × 1.0 = 5.1 V.

E = 6.0 V and r = 1.0 Ω.

Check: Both measured terminal voltages are below E, as expected during discharge.

Worked example 2

Track every watt

A 12 V cell with r = 1 Ω supplies a 5 Ω resistor. Find current, terminal voltage, load power, internal heating and efficiency.

Step-by-step explanation
  1. Total resistance is 6 Ω. Current I = 126\frac{12}{6} = 2 A. Terminal voltage is IR = 2 × 5 = 10 V.
  2. Load power = I2RI^{2}R = 4 × 5 = 20 W. Internal heating = I2rI^{2}r = 4 W. Source power EI = 24 W.
  3. Efficiency = 2024\frac{20}{24} = 56\frac{5}{6} ≈ 83.3%. The power balance is 24 = 20 + 4 W.

2 A, 10 V, 20 W useful, 4 W internal, 83.3% efficiency.

Check: Using 12 V directly across the 5 Ω load would ignore the internal voltage drop.

Worked example 3

Maximum power is a different goal

A source has E = 8 V and r = 2 Ω. Which of R = 1 Ω, 2 Ω and 8 Ω receives greatest power? Which has greatest efficiency?

Step-by-step explanation
  1. Compute E2R(R+r)2\frac{E^2R}{(R+r)^2}: at 1 Ω, 649\frac{64}{9} ≈ 7.11 W; at 2 Ω, 12816\frac{128}{16} = 8 W; at 8 Ω, 512100\frac{512}{100} = 5.12 W.
  2. Efficiency RR+r\frac{R}{R+r} is respectively 13\frac{1}{3}, 12\frac{1}{2} and 45\frac{4}{5}.
  3. The load matching r receives greatest power, while the largest load resistance has greatest efficiency among these choices.

Greatest power: 2 Ω at 8 W. Greatest efficiency: 8 Ω at 80%.

Check: The rankings differ because efficiency is a fraction while power is an absolute energy-transfer rate.

Mistakes worth catching

“The cell label gives the voltage across every load.”

The emf can exceed terminal voltage during discharge. Find the internal drop first.

“The slope is the resistance, regardless of the axes.”

For V against I it is −r. For I against V it is −1/r. Include units and the sign.

“Maximum power means maximum efficiency.”

At R = r the load gets maximum power in this model, but efficiency is only 50%.

Quick revision checklist
  • Choose the charge/discharge convention.
  • Use a full loop containing both external and internal resistance.
  • Read graph axes before converting slope to resistance.
  • Check EI = I2R+I2rI^2R+I^2r and distinguish watts from efficiency.

Practise with worked solutions

Problem 1

A real cell of fixed emf and internal resistance supplies current to an external load. Voltage is measured across its terminals. At current (A) = 0, terminal voltage (V) = 12. For each unit increase in current (A), the change in terminal voltage (V) is -0.5. Predict terminal voltage (V) at current (A) = 3.

Worked solution
  1. Choose the ruleV=E−IrV=E-Ir
  2. Why it appliesCharge loses energy inside a discharging cell. Terminal voltage falls from the open-circuit emf by the internal voltage drop.
  3. Work it outStart from the intercept and add the accumulated change: 12 + (-0.5) × 3.
  4. Resultterminal voltage (V) is 10.5.
Problem 2

A real cell of fixed emf and internal resistance supplies current to an external load. Voltage is measured across its terminals. Read each pair as (current (A), terminal voltage (V)). The observations are (1, 11.5) and (3, 10.5). Find the rate of change.

Worked solution
  1. Choose the ruleV=E−IrV=E-Ir
  2. Why it appliesCharge loses energy inside a discharging cell. Terminal voltage falls from the open-circuit emf by the internal voltage drop.
  3. Work it outSubtract corresponding outputs and inputs. The slope is (10.5 − 11.5) / (3 − 1).
  4. ResultThe signed rate is -0.5 output units per input unit.
Problem 3

A real cell of fixed emf and internal resistance supplies current to an external load. Voltage is measured across its terminals. Read each pair as (current (A), terminal voltage (V)). Using (1, 11.5) and (2, 11), reconstruct the reading at zero input.

Worked solution
  1. Choose the ruleV=E−IrV=E-Ir
  2. Why it appliesCharge loses energy inside a discharging cell. Terminal voltage falls from the open-circuit emf by the internal voltage drop.
  3. Work it outThe output changes by -0.5 per input step of 1. Move one such step backwards from (1, 11.5).
  4. ResultThe intercept is 11.5 − (-0.5) = 12.
Problem 4

A real cell of fixed emf and internal resistance supplies current to an external load. Voltage is measured across its terminals. The starting reading is 12 and the signed slope is -0.5. At what input is the output 10?

Worked solution
  1. Choose the ruleV=E−IrV=E-Ir
  2. Why it appliesCharge loses energy inside a discharging cell. Terminal voltage falls from the open-circuit emf by the internal voltage drop.
  3. Work it outSubtract the initial contribution to isolate the change: 10 − (12) = -2. Divide by the slope.
  4. Resultcurrent (A) = 4. Putting it into the model gives the stated output.
Problem 5

A real cell of fixed emf and internal resistance supplies current to an external load. Voltage is measured across its terminals. Read each pair as (current (A), terminal voltage (V)). Readings are (0, 12) and (4, 10). Estimate the output a quarter of the way between these input settings.

Worked solution
  1. Choose the ruleV=E−IrV=E-Ir
  2. Why it appliesCharge loses energy inside a discharging cell. Terminal voltage falls from the open-circuit emf by the internal voltage drop.
  3. Work it outA quarter of the input interval gives a quarter of the signed output difference: (10 − 12)/4 = -0.5.
  4. ResultAdd this to the first output to get 11.5.
Problem 6

A real cell of fixed emf and internal resistance supplies current to an external load. Voltage is measured across its terminals. You know the slope is -0.5 but the zero reading is lost. Can the change in output from input 1 to 3 still be found?

Worked solution
  1. Choose the ruleV=E−IrV=E-Ir
  2. Why it appliesCharge loses energy inside a discharging cell. Terminal voltage falls from the open-circuit emf by the internal voltage drop.
  3. Work it outSubtract the two model equations. Their common intercept cancels, leaving slope × change in input.
  4. ResultYes. The signed change is -0.5 × 2 = -1.
Problem 7

A real cell of fixed emf and internal resistance supplies current to an external load. Voltage is measured across its terminals. Read each pair as (current (A), terminal voltage (V)). Three measured pairs are (0, 12), (1, 11.5) and (2, 11.25). Are all three consistent with one constant rate?

Worked solution
  1. Choose the ruleV=E−IrV=E-Ir
  2. Why it appliesCharge loses energy inside a discharging cell. Terminal voltage falls from the open-circuit emf by the internal voltage drop.
  3. Work it outThe first interval changes the reading by -0.5. An equal second interval should give the same increment, predicting 11.
  4. ResultThe last observation lies 0.25 above the prediction, so the three cannot all fit the exact model.
Problem 8

A real cell of fixed emf and internal resistance supplies current to an external load. Voltage is measured across its terminals. Read each pair as (current (A), terminal voltage (V)). The true readings include (1, 11.5) and (3, 10.5). An instrument adds 2 units to every output. What happens to the inferred slope and intercept?

Worked solution
  1. Choose the ruleV=E−IrV=E-Ir
  2. Why it appliesCharge loses energy inside a discharging cell. Terminal voltage falls from the open-circuit emf by the internal voltage drop.
  3. Work it outThe added 2 cancels in differences. Recover the true intercept by subtracting one slope step from the first reading, then apply the offset.
  4. ResultSlope stays -0.5. The apparent intercept is 14 instead of 12.
Problem 9

A real cell of fixed emf and internal resistance supplies current to an external load. Voltage is measured across its terminals. Compare two models starting at the same output 12. Their signed slopes are -0.5 and -0.25. How far apart are the predictions at input 2?

Worked solution
  1. Choose the ruleV=E−IrV=E-Ir
  2. Why it appliesCharge loses energy inside a discharging cell. Terminal voltage falls from the open-circuit emf by the internal voltage drop.
  3. Work it outSubtract the slopes and multiply by input because the intercepts match. Use the magnitude for a separation.
  4. ResultThe separation is |-0.25 × 2| = 0.5 output units.
Problem 10

A real cell of fixed emf and internal resistance supplies current to an external load. Voltage is measured across its terminals. Read each pair as (current (A), terminal voltage (V)). Readings are (1, 11.5) and (3, 10.5). Redefine input zero at the first observation. What are the new intercept and the prediction two original input steps later?

Worked solution
  1. Choose the ruleV=E−IrV=E-Ir
  2. Why it appliesCharge loses energy inside a discharging cell. Terminal voltage falls from the open-circuit emf by the internal voltage drop.
  3. Work it outChanging the reference relabels the first input as zero. Its output 11.5 becomes the intercept. The slope is still -0.5.
  4. ResultAfter an input increase of 2, the prediction is 11.5 + (-0.5) × 2 = 10.5.