← Motors, induction and generators · formative

Class 10 Physics · 10 worked problems

Study the worked examples below, or retry these problems as a revision test.

Take topic test →

Changing flux and induced voltage

Average induced voltage measures how quickly flux linkage changes. A slower change spreads the same flux change over more time. ∣average emf∣=∣Δ(NΦ)∣Δt|\text{average emf}|=\frac{|\Delta(N\Phi)|}{\Delta t}.

Practise with worked solutions

Problem 1

A coil undergoes the same change of magnetic flux linkage in each trial. At duration = 0.2 s, mean voltage magnitude = 5 V. Predict mean voltage magnitude at duration = 0.4 s.

Worked solution
  1. Choose the rule∣average emf∣=∣Δ(NΦ)∣Δt|\text{average emf}|=\frac{|\Delta(N\Phi)|}{\Delta t}. With the other quantities fixed, the output changes by the reciprocal of the input factor.
  2. Why it appliesAverage induced voltage measures how quickly flux linkage changes. A slower change spreads the same flux change over more time.
  3. Work it outThe input ratio is 2. The output ratio is 2−12^{-1} = 0.5.
  4. ResultMultiply 5 V by 0.5 to obtain 2.5 V.
Problem 2

A coil undergoes the same change of magnetic flux linkage in each trial. At duration = 0.2 s, mean voltage magnitude = 5 V. A reading of mean voltage magnitude = 1.6667 V is required. Find the positive value of duration.

Worked solution
  1. Choose the rule∣average emf∣=∣Δ(NΦ)∣Δt|\text{average emf}|=\frac{|\Delta(N\Phi)|}{\Delta t}. With the other quantities fixed, the output changes by the reciprocal of the input factor.
  2. Why it appliesAverage induced voltage measures how quickly flux linkage changes. A slower change spreads the same flux change over more time.
  3. Work it outThe required output ratio is 0.33333. Undo the power by raising this ratio to 1/(-1), giving an input ratio of 3.
  4. ResultSet duration to 0.6 s. Substitution gives the required reading.
Problem 3

A coil undergoes the same change of magnetic flux linkage in each trial. At duration = 0.2 s, mean voltage magnitude = 5 V. Reduce duration by 20%. What percentage change should appear in mean voltage magnitude?

Worked solution
  1. Choose the rule∣average emf∣=∣Δ(NΦ)∣Δt|\text{average emf}|=\frac{|\Delta(N\Phi)|}{\Delta t}. With the other quantities fixed, the output changes by the reciprocal of the input factor.
  2. Why it appliesAverage induced voltage measures how quickly flux linkage changes. A slower change spreads the same flux change over more time.
  3. Work it outThe input ratio is 0.8. The output ratio is 0.8−10.8^{-1} = 1.25.
  4. ResultSubtract 1 from the ratio and multiply by 100. The result is a 25% increase.
Problem 4

A coil undergoes the same change of magnetic flux linkage in each trial. At duration = 0.2 s, mean voltage magnitude = 5 V. Two trials use duration = 0.1 s and 0.3 s. Compare the second output to the first.

Worked solution
  1. Choose the rule∣average emf∣=∣Δ(NΦ)∣Δt|\text{average emf}|=\frac{|\Delta(N\Phi)|}{\Delta t}. With the other quantities fixed, the output changes by the reciprocal of the input factor.
  2. Why it appliesAverage induced voltage measures how quickly flux linkage changes. A slower change spreads the same flux change over more time.
  3. Work it outTake the ratio between the trials directly: 0.30.1\frac{0.3}{0.1} = 3. The input ratio is 3. The output ratio is 3−13^{-1} = 0.33333.
  4. ResultThe second reading is 0.33333 times the first.
Problem 5

A coil undergoes the same change of magnetic flux linkage in each trial. At duration = 0.2 s, mean voltage magnitude = 5 V. A notebook records mean voltage magnitude = 3.125 V at duration = 0.4 s. Find the percentage discrepancy relative to the model.

Worked solution
  1. Choose the rule∣average emf∣=∣Δ(NΦ)∣Δt|\text{average emf}|=\frac{|\Delta(N\Phi)|}{\Delta t}. With the other quantities fixed, the output changes by the reciprocal of the input factor.
  2. Why it appliesAverage induced voltage measures how quickly flux linkage changes. A slower change spreads the same flux change over more time.
  3. Work it outThe input ratio is 2. The output ratio is 2−12^{-1} = 0.5. The expected reading is 2.5 V. Use (recorded − expected)/expected.
  4. ResultThe recorded value is 1.25 times the prediction, or 25% above it.
Problem 6

A coil undergoes the same change of magnetic flux linkage in each trial. At duration = 0.2 s, mean voltage magnitude = 5 V. The two available settings for duration are 0.2 s and 0.4 s. Which gives mean voltage magnitude closer to 3.25 V?

Worked solution
  1. Choose the rule∣average emf∣=∣Δ(NΦ)∣Δt|\text{average emf}|=\frac{|\Delta(N\Phi)|}{\Delta t}. With the other quantities fixed, the output changes by the reciprocal of the input factor.
  2. Why it appliesAverage induced voltage measures how quickly flux linkage changes. A slower change spreads the same flux change over more time.
  3. Work it outThe predicted outputs are 5 V and 2.5 V. Compare absolute errors: 1.75 V and 0.75 V respectively.
  4. ResultChoose 0.4 s because its predicted reading lies closer to the target.
Problem 7

A coil undergoes the same change of magnetic flux linkage in each trial. At duration = 0.2 s, mean voltage magnitude = 5 V. Increase duration by 50%, then reduce the new value by one third. Predict the final mean voltage magnitude and explain.

Worked solution
  1. Choose the rule∣average emf∣=∣Δ(NΦ)∣Δt|\text{average emf}|=\frac{|\Delta(N\Phi)|}{\Delta t}. With the other quantities fixed, the output changes by the reciprocal of the input factor.
  2. Why it appliesAverage induced voltage measures how quickly flux linkage changes. A slower change spreads the same flux change over more time.
  3. Work it outThe combined input factor is (32\frac{3}{2}) × (23\frac{2}{3}) = 1. The final model therefore has the original input and constants.
  4. ResultThe reading returns to 5 V. Percentages at successive steps refer to different starting values.
Problem 8

A coil undergoes the same change of magnetic flux linkage in each trial. At duration = 0.2 s, mean voltage magnitude = 5 V. The actual duration lies between 0.18 s and 0.22 s. Bound mean voltage magnitude under this model.

Worked solution
  1. Choose the rule∣average emf∣=∣Δ(NΦ)∣Δt|\text{average emf}|=\frac{|\Delta(N\Phi)|}{\Delta t}. With the other quantities fixed, the output changes by the reciprocal of the input factor.
  2. Why it appliesAverage induced voltage measures how quickly flux linkage changes. A slower change spreads the same flux change over more time.
  3. Work it outFor positive inputs the power is monotonic. Evaluate the endpoints: 5.5556 V at the low input and 4.5455 V at the high input.
  4. ResultIn ascending order the bounds are 4.5455 V and 5.5556 V.
Problem 9

A coil undergoes the same change of magnetic flux linkage in each trial. At duration = 0.2 s, mean voltage magnitude = 5 V. A student averages the outputs at 0.1 s and 0.3 s to estimate the output at 0.2 s. Does that give the exact value?

Worked solution
  1. Choose the rule∣average emf∣=∣Δ(NΦ)∣Δt|\text{average emf}|=\frac{|\Delta(N\Phi)|}{\Delta t}. With the other quantities fixed, the output changes by the reciprocal of the input factor.
  2. Why it appliesAverage induced voltage measures how quickly flux linkage changes. A slower change spreads the same flux change over more time.
  3. Work it outCompute the individual predictions 10 V and 3.3333 V. Their mean is 6.6667 V.
  4. ResultNo. The model gives 5 V at the midpoint. A nonlinear power does not preserve this average.
Problem 10

A coil undergoes the same change of magnetic flux linkage in each trial. At duration = 0.2 s, mean voltage magnitude = 5 V. The output changes from 10 V to 2.5 V. Recover both input settings and their difference.

Worked solution
  1. Choose the rule∣average emf∣=∣Δ(NΦ)∣Δt|\text{average emf}|=\frac{|\Delta(N\Phi)|}{\Delta t}. With the other quantities fixed, the output changes by the reciprocal of the input factor.
  2. Why it appliesAverage induced voltage measures how quickly flux linkage changes. A slower change spreads the same flux change over more time.
  3. Work it outDivide each reading by 5 V and raise to the reciprocal power. The resulting input ratios are 0.5 and 2.
  4. ResultThe settings are 0.1 s and 0.4 s, separated by 0.3 s.