Field around a current-carrying wire

Circular field lines surround the wire. In this long-wire model the same current produces a weaker field at larger radial distances. B=μ0I2πrB=\frac{\mu_0 I}{2\pi r}.

Practise with worked solutions

Problem 1

Measure the field outside a long straight wire at fixed current, far from its ends. At radial distance = 2 cm, field magnitude = 40 μT. Predict field magnitude at radial distance = 4 cm.

Worked solution
  1. Choose the ruleB=μ0I2πrB=\frac{\mu_0 I}{2\pi r}. With the other quantities fixed, the output changes by the reciprocal of the input factor.
  2. Why it appliesCircular field lines surround the wire. In this long-wire model the same current produces a weaker field at larger radial distances.
  3. Work it outThe input ratio is 2. The output ratio is 2−12^{-1} = 0.5.
  4. ResultMultiply 40 μT by 0.5 to obtain 20 μT.
Problem 2

Measure the field outside a long straight wire at fixed current, far from its ends. At radial distance = 2 cm, field magnitude = 40 μT. A reading of field magnitude = 13.333 μT is required. Find the positive value of radial distance.

Worked solution
  1. Choose the ruleB=μ0I2πrB=\frac{\mu_0 I}{2\pi r}. With the other quantities fixed, the output changes by the reciprocal of the input factor.
  2. Why it appliesCircular field lines surround the wire. In this long-wire model the same current produces a weaker field at larger radial distances.
  3. Work it outThe required output ratio is 0.33333. Undo the power by raising this ratio to 1/(-1), giving an input ratio of 3.
  4. ResultSet radial distance to 6 cm. Substitution gives the required reading.
Problem 3

Measure the field outside a long straight wire at fixed current, far from its ends. At radial distance = 2 cm, field magnitude = 40 μT. Reduce radial distance by 20%. What percentage change should appear in field magnitude?

Worked solution
  1. Choose the ruleB=μ0I2πrB=\frac{\mu_0 I}{2\pi r}. With the other quantities fixed, the output changes by the reciprocal of the input factor.
  2. Why it appliesCircular field lines surround the wire. In this long-wire model the same current produces a weaker field at larger radial distances.
  3. Work it outThe input ratio is 0.8. The output ratio is 0.8−10.8^{-1} = 1.25.
  4. ResultSubtract 1 from the ratio and multiply by 100. The result is a 25% increase.
Problem 4

Measure the field outside a long straight wire at fixed current, far from its ends. At radial distance = 2 cm, field magnitude = 40 μT. Two trials use radial distance = 1 cm and 3 cm. Compare the second output to the first.

Worked solution
  1. Choose the ruleB=μ0I2πrB=\frac{\mu_0 I}{2\pi r}. With the other quantities fixed, the output changes by the reciprocal of the input factor.
  2. Why it appliesCircular field lines surround the wire. In this long-wire model the same current produces a weaker field at larger radial distances.
  3. Work it outTake the ratio between the trials directly: 31\frac{3}{1} = 3. The input ratio is 3. The output ratio is 3−13^{-1} = 0.33333.
  4. ResultThe second reading is 0.33333 times the first.
Problem 5

Measure the field outside a long straight wire at fixed current, far from its ends. At radial distance = 2 cm, field magnitude = 40 μT. A notebook records field magnitude = 25 μT at radial distance = 4 cm. Find the percentage discrepancy relative to the model.

Worked solution
  1. Choose the ruleB=μ0I2πrB=\frac{\mu_0 I}{2\pi r}. With the other quantities fixed, the output changes by the reciprocal of the input factor.
  2. Why it appliesCircular field lines surround the wire. In this long-wire model the same current produces a weaker field at larger radial distances.
  3. Work it outThe input ratio is 2. The output ratio is 2−12^{-1} = 0.5. The expected reading is 20 μT. Use (recorded − expected)/expected.
  4. ResultThe recorded value is 1.25 times the prediction, or 25% above it.
Problem 6

Measure the field outside a long straight wire at fixed current, far from its ends. At radial distance = 2 cm, field magnitude = 40 μT. The two available settings for radial distance are 2 cm and 4 cm. Which gives field magnitude closer to 26 μT?

Worked solution
  1. Choose the ruleB=μ0I2πrB=\frac{\mu_0 I}{2\pi r}. With the other quantities fixed, the output changes by the reciprocal of the input factor.
  2. Why it appliesCircular field lines surround the wire. In this long-wire model the same current produces a weaker field at larger radial distances.
  3. Work it outThe predicted outputs are 40 μT and 20 μT. Compare absolute errors: 14 μT and 6 μT respectively.
  4. ResultChoose 4 cm because its predicted reading lies closer to the target.
Problem 7

Measure the field outside a long straight wire at fixed current, far from its ends. At radial distance = 2 cm, field magnitude = 40 μT. Increase radial distance by 50%, then reduce the new value by one third. Predict the final field magnitude and explain.

Worked solution
  1. Choose the ruleB=μ0I2πrB=\frac{\mu_0 I}{2\pi r}. With the other quantities fixed, the output changes by the reciprocal of the input factor.
  2. Why it appliesCircular field lines surround the wire. In this long-wire model the same current produces a weaker field at larger radial distances.
  3. Work it outThe combined input factor is (32\frac{3}{2}) × (23\frac{2}{3}) = 1. The final model therefore has the original input and constants.
  4. ResultThe reading returns to 40 μT. Percentages at successive steps refer to different starting values.
Problem 8

Measure the field outside a long straight wire at fixed current, far from its ends. At radial distance = 2 cm, field magnitude = 40 μT. The actual radial distance lies between 1.8 cm and 2.2 cm. Bound field magnitude under this model.

Worked solution
  1. Choose the ruleB=μ0I2πrB=\frac{\mu_0 I}{2\pi r}. With the other quantities fixed, the output changes by the reciprocal of the input factor.
  2. Why it appliesCircular field lines surround the wire. In this long-wire model the same current produces a weaker field at larger radial distances.
  3. Work it outFor positive inputs the power is monotonic. Evaluate the endpoints: 44.444 μT at the low input and 36.364 μT at the high input.
  4. ResultIn ascending order the bounds are 36.364 μT and 44.444 μT.
Problem 9

Measure the field outside a long straight wire at fixed current, far from its ends. At radial distance = 2 cm, field magnitude = 40 μT. A student averages the outputs at 1 cm and 3 cm to estimate the output at 2 cm. Does that give the exact value?

Worked solution
  1. Choose the ruleB=μ0I2πrB=\frac{\mu_0 I}{2\pi r}. With the other quantities fixed, the output changes by the reciprocal of the input factor.
  2. Why it appliesCircular field lines surround the wire. In this long-wire model the same current produces a weaker field at larger radial distances.
  3. Work it outCompute the individual predictions 80 μT and 26.667 μT. Their mean is 53.333 μT.
  4. ResultNo. The model gives 40 μT at the midpoint. A nonlinear power does not preserve this average.
Problem 10

Measure the field outside a long straight wire at fixed current, far from its ends. At radial distance = 2 cm, field magnitude = 40 μT. The output changes from 80 μT to 20 μT. Recover both input settings and their difference.

Worked solution
  1. Choose the ruleB=μ0I2πrB=\frac{\mu_0 I}{2\pi r}. With the other quantities fixed, the output changes by the reciprocal of the input factor.
  2. Why it appliesCircular field lines surround the wire. In this long-wire model the same current produces a weaker field at larger radial distances.
  3. Work it outDivide each reading by 40 μT and raise to the reciprocal power. The resulting input ratios are 0.5 and 2.
  4. ResultThe settings are 1 cm and 4 cm, separated by 3 cm.