← Electricity

Class 10 Physics · 10 worked problems

Study the worked examples below, or retry these problems as a revision test.

Take topic test →

Resistivity and wire dimensions

At fixed resistivity and length, a larger area gives parallel paths for charge to flow, reducing resistance. R=ρLAR=\frac{\rho L}{A}.

Practise with worked solutions

Problem 1

Compare uniform wires of the same material, length and temperature, varying only cross-sectional area. At cross-sectional area = 2 mm2\mathrm{mm}^{2}, resistance = 6 Ω. Predict resistance at cross-sectional area = 4 mm2\mathrm{mm}^{2}.

Worked solution
  1. Choose the ruleR=ρLAR=\frac{\rho L}{A}. With the other quantities fixed, the output changes by the reciprocal of the input factor.
  2. Why it appliesAt fixed resistivity and length, a larger area gives parallel paths for charge to flow, reducing resistance.
  3. Work it outThe input ratio is 2. The output ratio is 2−12^{-1} = 0.5.
  4. ResultMultiply 6 Ω by 0.5 to obtain 3 Ω.
Problem 2

Compare uniform wires of the same material, length and temperature, varying only cross-sectional area. At cross-sectional area = 2 mm2\mathrm{mm}^{2}, resistance = 6 Ω. A reading of resistance = 2 Ω is required. Find the positive value of cross-sectional area.

Worked solution
  1. Choose the ruleR=ρLAR=\frac{\rho L}{A}. With the other quantities fixed, the output changes by the reciprocal of the input factor.
  2. Why it appliesAt fixed resistivity and length, a larger area gives parallel paths for charge to flow, reducing resistance.
  3. Work it outThe required output ratio is 0.33333. Undo the power by raising this ratio to 1/(-1), giving an input ratio of 3.
  4. ResultSet cross-sectional area to 6 mm2\mathrm{mm}^{2}. Substitution gives the required reading.
Problem 3

Compare uniform wires of the same material, length and temperature, varying only cross-sectional area. At cross-sectional area = 2 mm2\mathrm{mm}^{2}, resistance = 6 Ω. Reduce cross-sectional area by 20%. What percentage change should appear in resistance?

Worked solution
  1. Choose the ruleR=ρLAR=\frac{\rho L}{A}. With the other quantities fixed, the output changes by the reciprocal of the input factor.
  2. Why it appliesAt fixed resistivity and length, a larger area gives parallel paths for charge to flow, reducing resistance.
  3. Work it outThe input ratio is 0.8. The output ratio is 0.8−10.8^{-1} = 1.25.
  4. ResultSubtract 1 from the ratio and multiply by 100. The result is a 25% increase.
Problem 4

Compare uniform wires of the same material, length and temperature, varying only cross-sectional area. At cross-sectional area = 2 mm2\mathrm{mm}^{2}, resistance = 6 Ω. Two trials use cross-sectional area = 1 mm2\mathrm{mm}^{2} and 3 mm2\mathrm{mm}^{2}. Compare the second output to the first.

Worked solution
  1. Choose the ruleR=ρLAR=\frac{\rho L}{A}. With the other quantities fixed, the output changes by the reciprocal of the input factor.
  2. Why it appliesAt fixed resistivity and length, a larger area gives parallel paths for charge to flow, reducing resistance.
  3. Work it outTake the ratio between the trials directly: 31\frac{3}{1} = 3. The input ratio is 3. The output ratio is 3−13^{-1} = 0.33333.
  4. ResultThe second reading is 0.33333 times the first.
Problem 5

Compare uniform wires of the same material, length and temperature, varying only cross-sectional area. At cross-sectional area = 2 mm2\mathrm{mm}^{2}, resistance = 6 Ω. A notebook records resistance = 3.75 Ω at cross-sectional area = 4 mm2\mathrm{mm}^{2}. Find the percentage discrepancy relative to the model.

Worked solution
  1. Choose the ruleR=ρLAR=\frac{\rho L}{A}. With the other quantities fixed, the output changes by the reciprocal of the input factor.
  2. Why it appliesAt fixed resistivity and length, a larger area gives parallel paths for charge to flow, reducing resistance.
  3. Work it outThe input ratio is 2. The output ratio is 2−12^{-1} = 0.5. The expected reading is 3 Ω. Use (recorded − expected)/expected.
  4. ResultThe recorded value is 1.25 times the prediction, or 25% above it.
Problem 6

Compare uniform wires of the same material, length and temperature, varying only cross-sectional area. At cross-sectional area = 2 mm2\mathrm{mm}^{2}, resistance = 6 Ω. The two available settings for cross-sectional area are 2 mm2\mathrm{mm}^{2} and 4 mm2\mathrm{mm}^{2}. Which gives resistance closer to 3.9 Ω?

Worked solution
  1. Choose the ruleR=ρLAR=\frac{\rho L}{A}. With the other quantities fixed, the output changes by the reciprocal of the input factor.
  2. Why it appliesAt fixed resistivity and length, a larger area gives parallel paths for charge to flow, reducing resistance.
  3. Work it outThe predicted outputs are 6 Ω and 3 Ω. Compare absolute errors: 2.1 Ω and 0.9 Ω respectively.
  4. ResultChoose 4 mm2\mathrm{mm}^{2} because its predicted reading lies closer to the target.
Problem 7

Compare uniform wires of the same material, length and temperature, varying only cross-sectional area. At cross-sectional area = 2 mm2\mathrm{mm}^{2}, resistance = 6 Ω. Increase cross-sectional area by 50%, then reduce the new value by one third. Predict the final resistance and explain.

Worked solution
  1. Choose the ruleR=ρLAR=\frac{\rho L}{A}. With the other quantities fixed, the output changes by the reciprocal of the input factor.
  2. Why it appliesAt fixed resistivity and length, a larger area gives parallel paths for charge to flow, reducing resistance.
  3. Work it outThe combined input factor is (32\frac{3}{2}) × (23\frac{2}{3}) = 1. The final model therefore has the original input and constants.
  4. ResultThe reading returns to 6 Ω. Percentages at successive steps refer to different starting values.
Problem 8

Compare uniform wires of the same material, length and temperature, varying only cross-sectional area. At cross-sectional area = 2 mm2\mathrm{mm}^{2}, resistance = 6 Ω. The actual cross-sectional area lies between 1.8 mm2\mathrm{mm}^{2} and 2.2 mm2\mathrm{mm}^{2}. Bound resistance under this model.

Worked solution
  1. Choose the ruleR=ρLAR=\frac{\rho L}{A}. With the other quantities fixed, the output changes by the reciprocal of the input factor.
  2. Why it appliesAt fixed resistivity and length, a larger area gives parallel paths for charge to flow, reducing resistance.
  3. Work it outFor positive inputs the power is monotonic. Evaluate the endpoints: 6.6667 Ω at the low input and 5.4545 Ω at the high input.
  4. ResultIn ascending order the bounds are 5.4545 Ω and 6.6667 Ω.
Problem 9

Compare uniform wires of the same material, length and temperature, varying only cross-sectional area. At cross-sectional area = 2 mm2\mathrm{mm}^{2}, resistance = 6 Ω. A student averages the outputs at 1 mm2\mathrm{mm}^{2} and 3 mm2\mathrm{mm}^{2} to estimate the output at 2 mm2\mathrm{mm}^{2}. Does that give the exact value?

Worked solution
  1. Choose the ruleR=ρLAR=\frac{\rho L}{A}. With the other quantities fixed, the output changes by the reciprocal of the input factor.
  2. Why it appliesAt fixed resistivity and length, a larger area gives parallel paths for charge to flow, reducing resistance.
  3. Work it outCompute the individual predictions 12 Ω and 4 Ω. Their mean is 8 Ω.
  4. ResultNo. The model gives 6 Ω at the midpoint. A nonlinear power does not preserve this average.
Problem 10

Compare uniform wires of the same material, length and temperature, varying only cross-sectional area. At cross-sectional area = 2 mm2\mathrm{mm}^{2}, resistance = 6 Ω. The output changes from 12 Ω to 3 Ω. Recover both input settings and their difference.

Worked solution
  1. Choose the ruleR=ρLAR=\frac{\rho L}{A}. With the other quantities fixed, the output changes by the reciprocal of the input factor.
  2. Why it appliesAt fixed resistivity and length, a larger area gives parallel paths for charge to flow, reducing resistance.
  3. Work it outDivide each reading by 6 Ω and raise to the reciprocal power. The resulting input ratios are 0.5 and 2.
  4. ResultThe settings are 1 mm2\mathrm{mm}^{2} and 4 mm2\mathrm{mm}^{2}, separated by 3 mm2\mathrm{mm}^{2}.