← NSEP physics · Optics & modern physics

NSEP preparation · Physics · Optics & modern physics

Experimental physics: errors, graphs and the standard experiments

Read instruments with zero corrections, propagate errors to find which measurement dominates, linearise laws to read constants from slopes and intercepts, and reason through NSEP's standard laboratory experiments.

What you’ll be able to do

  • Read vernier calipers and screw gauges, including positive and negative zero errors.
  • Distinguish systematic from random errors and propagate uncertainties to identify the measurement that limits a result.
  • Choose axes that turn a physical law into a straight line and extract constants from its slope and intercept.
  • Explain the method, the corrections and the dominant error in the standard experiments: pendulum, Searle's apparatus, metre bridge, potentiometer, lens u–v, resonance tube and calorimetry.

Before you start: Units and dimensions, logarithms, the straight-line equation y = mx + c, and the physics of the experiments concerned: simple harmonic motion, elasticity, current electricity, thin lenses, standing waves in pipes and calorimetry.

Reading instruments: least count and zero error

A vernier with n vernier divisions equal to n − 1 main-scale divisions of size s has least count LC=1 MSD−1 VSD=s/n\mathrm{LC} = 1\ \mathrm{MSD} - 1\ \mathrm{VSD} = s/n. The reading is the main-scale reading just before the vernier zero plus the number of the coinciding vernier division times LC. With the jaws closed, if the vernier zero lies to the right of the main zero and division k coincides, the zero error is +k × LC; if it lies to the left, the error is −(n − k) × LC. Always correct by subtracting the zero error with its sign: true value = reading − zero error, so a negative error is effectively added.

A screw gauge of pitch p with N divisions on the thimble has LC = p/N, and its zero error is handled the same way. Turn the thimble in one direction only when closing on the object, to avoid backlash, and use the ratchet so that the contact force is the same every time. A single reading is uncertain by about one least count, and a length found from two readings, such as a difference of positions, carries both uncertainties. Choose instruments to keep relative errors small: a 0.5 mm wire measured to 0.01 mm is still uncertain by 2%, while a 2 m wire measured to 1 mm is uncertain by only 0.05%.

Timing follows the same logic. A human starting and stopping a watch introduces a random error of roughly 0.1–0.2 s, independent of the interval being timed, so time many oscillations and divide: the relative error falls in proportion to the number counted. Start the count as the bob passes the centre of its swing, where it moves fastest and its position is most sharply defined.

Errors: systematic, random and how they propagate

Systematic errors shift every reading the same way: an uncorrected zero error, a watch that runs fast, heat lost to the room, an end correction ignored, parallax from always looking from the same side. Repetition does not reduce them; they must be corrected or designed out, for example by reading a constant from a graph's slope so that an unknown offset falls into the intercept, or by interchanging two parts of the apparatus and averaging. Random errors scatter readings both ways; averaging N readings reduces the uncertainty of the mean by about √N. A precise result has small scatter; an accurate one is close to the true value; a precise result with an uncorrected systematic error is neither accurate nor honest.

For sums and differences, maximum absolute errors add: Δ(A±B)=ΔA+ΔB\Delta(A \pm B) = \Delta A + \Delta B, which is why a small difference of two nearly equal large quantities is badly determined. For a product of powers Z=AaBb/CcZ = A^aB^b/C^c, maximum relative errors add, weighted by the powers: ΔZ/Z=∣a∣ΔA/A+∣b∣ΔB/B+∣c∣ΔC/C\Delta Z/Z = |a|\Delta A/A + |b|\Delta B/B + |c|\Delta C/C. Independent random errors are better combined in quadrature, the square root of the sum of squares, which gives a smaller and more realistic estimate. Either way, find the term with the largest power times relative error and improve that measurement first: the wire's diameter in Searle's experiment, the tube radius (fourth power) in Poiseuille's method, the period (squared) in the pendulum.

Quote results to match their uncertainty: the uncertainty to one or two significant figures, and the value to the same decimal place. A result of g = 9.8126 ± 0.05 m/s2s^{2} should be written 9.81 ± 0.05 m/s2s^{2}. For functions other than powers, differentiate: for example Δ(sin⁡θ\sin \theta ) = cos⁡θ\cos \theta Δθ with Δθ in radians, which is why angles near 90° give sines that are insensitive to the angle.

Graphs: linearise, then read slope and intercept

Rearrange the law into the form y = mx + c, with measured quantities on the axes and the unknowns in m and c. A pendulum with thread length l and bob radius r obeys T2=(4π2/g)(l+r)T^2 = (4\pi^2/g)(l + r): plot T2T^{2} against l, read g from the slope and −r from the intercept on the l axis. A thin lens obeys 1/v − 1/u = 1/f in the Cartesian convention: plot 1/v against 1/u to get slope +1 and intercept 1/f. A power law y = kxnkx^{n} becomes a straight line on log⁡\log y against log⁡\log x with slope n; an exponential decay y=y0e−t/τy = y_0e^{-t/\tau} becomes a straight line of ln⁡\ln y against t with slope −1/τ, as do Newton's cooling with ln⁡\ln (T − T0T_{0}) and a discharging capacitor.

Graphs do more than average. They reveal points that are wrong, show where a law stops holding, such as the period growing at large amplitude, and push unknown constant errors into the intercept so that the slope is free of them. Draw the best straight line through the points, not through the first and last points, and take the slope from two widely separated points on that line. A false origin is fine for reading slopes, but an intercept must be read at the true zero of the other variable or calculated from the line's equation. The uncertainty in a slope can be estimated from the steepest and shallowest lines that still pass reasonably through the data.

Standard mechanical, thermal and acoustic experiments

Searle's apparatus measures Young's modulus as Y=MgL/(πr2ΔL)Y = MgL/(\pi r^2\Delta L). A second, unloaded reference wire hanging from the same support cancels thermal expansion and sagging of the support; the extension is read with a micrometer and spirit level. The radius enters squared and is only about 0.25 mm, so it dominates the error: measure the diameter at several places and in two perpendicular directions. In the simple pendulum keep the amplitude small, time many oscillations from the mean position, and measure length to the centre of the bob, or eliminate the bob radius with a graph.

In the resonance tube, a tuning fork of frequency f over a tube closed by water gives the first two resonances at lengths L1L_{1} and L2L_{2} with L1+e=λ/4L_1 + e = \lambda/4 and L2+e=3λ/4L_2 + e = 3\lambda/4, where e ≈ 0.3d is the end correction for a tube of diameter d. Subtracting gives λ = 2(L2L_{2} − L1L_{1}) free of e, and v = 2f(L2L_{2} − L1L_{1}); the end correction itself is e = (L2L_{2} − 3L13L_{1})/2. In the method of mixtures, heat lost to the surroundings makes the final temperature too low and the measured specific heat of the hot body too small; it is reduced by insulating and stirring, and corrected by starting the water as far below room temperature as it will finish above it, or by a cooling-curve correction.

Standard electrical and optical experiments

The metre bridge is a Wheatstone bridge: with a known R in the left gap and unknown X in the right, balance at l cm from the left gives X=R(100−l)/lX = R(100 - l)/l. Choose R so that the balance falls near the middle, where the fractional error from locating the balance point is smallest, and remove end resistances by interchanging R and X and averaging. Never slide the jockey along the wire; tap it. The potentiometer is a null instrument: at balance it draws no current from the cell under test, so it measures emf rather than terminal voltage. Two cells compare as E1E_{1}/E2E_{2} = l1l_{1}/l2l_{2}; shunting a cell with resistance R shortens the balance length from l1l_{1} to l2l_{2}, giving the internal resistance r=R(l1/l2−1)r = R(l_1/l_2 - 1). The driver cell must have a larger emf than any cell to be balanced, or there is no balance point at all.

For the focal length of a convex lens or concave mirror by the u–v method, remove parallax between image and needle, apply the index correction found by measuring a rod of known length between the pins, and plot 1/v against 1/u rather than v against u, which gives a hyperbola. The point on the u–v curve where the magnitudes of u and v are equal gives 2f, a useful check. For a convex lens the minimum separation of object and real image is 4f, at u = v = 2f, which also fixes the bench length needed for the experiment.

Rules and when they apply

LC=1 MSD−1 VSD=sn\mathrm{LC} = 1\ \mathrm{MSD} - 1\ \mathrm{VSD} = \dfrac{s}{n}
Least count of a vernier whose n divisions span n − 1 main-scale divisions of size s; for a screw gauge LC = pitch/number of thimble divisions.

Standard direct vernier; corrected reading = observed reading − zero error (with its sign).

ΔZZ=∣a∣ΔAA+∣b∣ΔBB+∣c∣ΔCC\dfrac{\Delta Z}{Z} = |a|\dfrac{\Delta A}{A} + |b|\dfrac{\Delta B}{B} + |c|\dfrac{\Delta C}{C}
Maximum relative error in Z = A^a B^b / C^c from the relative errors of the measured quantities.

Small errors; for independent random errors combine the terms in quadrature instead.

T2=4π2g (l+r)T^2 = \dfrac{4\pi^2}{g}\,(l + r)
Simple pendulum with thread length l and bob radius r: slope of T2T^{2} against l is 4π24\pi ^{2}/g and the l-intercept is −r.

Small amplitude (below about 10°), light inextensible thread, negligible air drag.

X=R 100−llX = R\,\dfrac{100 - l}{l}
Unknown resistance X in the right gap of a metre bridge, known R in the left, balance at l cm from the left end.

Uniform wire and negligible end resistances; balance near 50 cm gives the smallest error.

r=R(l1l2−1)r = R\left(\dfrac{l_1}{l_2} - 1\right)
Internal resistance of a cell from potentiometer balance lengths l1l_{1} (cell on open circuit) and l2l_{2} (cell shunted by R).

Steady driver current and a driver emf larger than the cell's, so both balance points lie on the wire.

λ=2(L2−L1),e=L2−3L12\lambda = 2(L_2 - L_1),\quad e = \dfrac{L_2 - 3L_1}{2}
Wavelength and end correction from the first two resonance lengths of a tube closed at one end.

Same tuning fork and tube for both resonances, temperature constant during the readings.

Follow the reasoning

Worked example 1

A wire's diameter for Searle's experiment

A screw gauge has a pitch of 0.5 mm and 50 thimble divisions. With the jaws closed it reads +0.03 mm. On a wire, the main scale shows 0.5 mm and the 37th thimble division is on the reference line. Find the corrected diameter, and the percentage error this contributes to Young's modulus if each reading is uncertain by one least count.

Step-by-step explanation
  1. Least count = 0.550\frac{0.5}{50} = 0.01 mm.
  2. Observed reading = 0.5 + 37 × 0.01 = 0.87 mm; corrected diameter = 0.87 − (+0.03) = 0.84 mm.
  3. Relative error in d = 0.010.84\frac{0.01}{0.84} = 1.2%. Young's modulus depends on 1/d2d^{2}, so this contributes 2 × 1.2 ≈ 2.4%.

d = 0.84 ± 0.01 mm, contributing about 2.4% to the error in Y.

Check: Compare a 2.000 m length measured to 1 mm, only 0.05%: the diameter term is about fifty times larger, which is exactly why the guide says to measure the diameter at several places.

Worked example 2

Removing an unknown bob radius

A student measures thread lengths l from the support to the top of the bob, but not the bob's radius. With l = 60.0 cm the period is 1.568 s; with l = 100.0 cm it is 2.017 s. Find g and the bob radius, and the value of g the student would get from the first reading alone, treating l as the pendulum length.

Step-by-step explanation
  1. Use T2T^{2} = (4π24\pi ^{2}/g)(l + r). The squares are 1.5682568^{2} = 2.459 s2s^{2} and 2.0172017^{2} = 4.068 s2s^{2}.
  2. Slope = (4.068 − 2.459)/(1.000 − 0.600) = 4.024 s2s^{2}/m, so g = 4π24\pi ^{2}/4.024 = 9.81 m/s2s^{2}.
  3. From the first point, l + r = 2.4594.024\frac{2.459}{4.024} = 0.611 m, so r = 1.1 cm.
  4. Using l = 0.600 m alone gives g = 4π24\pi ^{2} × 0.6002.459\frac{0.600}{2.459} = 9.63 m/s2s^{2}, about 2% low: ignoring r is a systematic error that repetition would never reveal.

g ≈ 9.81 m/s2s^{2} and r ≈ 1.1 cm; the single-reading method gives 9.63 m/s2s^{2}.

Check: With r = 1.1 cm the second length is 1.011 m, and 2π√(1.0119.81\frac{1.011}{9.81}) = 2.017 s, reproducing the second measurement.

Worked example 3

Where should a metre bridge balance?

The balance point of a metre bridge can be located to ±0.1 cm. Find the fractional error in X = R(100 − l)/l for balance at l = 20.0 cm, 50.0 cm and 90.0 cm, and show where it is smallest.

Step-by-step explanation
  1. Error in l produces errors in both l and 100 − l, adding: ΔXX=Δl(1l+1100−l)=100 Δll(100−l)\dfrac{\Delta X}{X} = \Delta l\left(\dfrac{1}{l} + \dfrac{1}{100 - l}\right) = \dfrac{100\,\Delta l}{l(100 - l)}.
  2. With Δl = 0.1 cm: at 20.0 cm, 101600\frac{10}{1600} = 0.63%; at 50.0 cm, 102500\frac{10}{2500} = 0.40%; at 90.0 cm, 10900\frac{10}{900} = 1.1%.
  3. The denominator l(100 − l) is largest at l = 50 cm, so the error is smallest when R is chosen close to X.

0.63%, 0.40% and 1.1%; the error is least for balance at the middle of the wire.

Check: The formula is symmetric under l → 100 − l, as it must be since interchanging R and X mirrors the balance point, and it blows up as l approaches either end, where a tiny shift in l changes X enormously.

Mistakes worth catching

“Taking the mean of many readings removes a zero error.”

A zero error shifts every reading by the same amount, so the mean carries it too. Averaging reduces only random scatter; systematic errors must be corrected.

“A negative zero error is subtracted from the reading.”

The rule is corrected value = reading − zero error. With a negative zero error, subtracting it means adding its magnitude.

“The percentage error in g from a pendulum is just ΔT/T plus ΔL/L.”

g = 4π2L4\pi ^{2}L/T2T^{2} depends on T squared, so the period contributes 2ΔT/T. That is why many oscillations are timed.

“Plotting v against u for a lens should give a straight line.”

v against u is a hyperbola. Plot 1/v against 1/u, which is straight with slope +1 in the Cartesian convention, and read 1/f from the intercept.

“A potentiometer and a good voltmeter measure the same thing.”

A voltmeter draws current, so it reads the terminal voltage E − Ir; at balance a potentiometer draws none from the cell and so measures its emf.

Quick revision checklist
  • Corrected reading = observed reading − zero error, keeping the sign of the zero error.
  • Averaging beats random error by √N but never touches systematic error.
  • Relative errors add weighted by powers; improve the term with the largest weighted error first.
  • Linearise: T2T^{2} against l, 1/v against 1/u, log⁡\log –log⁡\log for powers, ln⁡\ln y against t for decays.
  • Metre bridge best near 50 cm; potentiometer measures emf; resonance tube λ = 2(L2L_{2} − L1L_{1}).

Try it without the worked examples

Ten separately written NSEP-level questions. Your answers are saved on this browser; finish to see the score and explanations.

Take the chapter test →