← IJSO Experimental skills

IJSO preparation · Experimental skills · Foundation to bridge

Measurement, uncertainty and fair tests

Choose controls, interpret repeats and use uncertainty to judge whether a result supports a claim.

What you’ll be able to do

  • Distinguish repeatability, resolution and calibration bias.
  • Use differences and slopes with units.
  • Plan a fair test and limit a conclusion to what the data support.

Before you start: Mean, range, graph axes, percentages and simple proportionality. Any uncertainty convention used in a numerical task is stated explicitly.

Repeats and calibration answer different questions

Repeated readings show how much results vary under similar conditions. Their mean can reduce the effect of random variation, but a constant calibration offset can remain in every reading. An instrument can be very repeatable while giving biased values.

Resolution is the smallest displayed or marked increment. It does not, by itself, establish total accuracy. A task may assign a reading uncertainty such as half a division; use that stated convention rather than claiming it is a universal instrument rule.

A useful graph is a test of a relationship

Place the independent variable on the horizontal axis unless the task specifies otherwise, label units and inspect the intercept. For y = a + bx, differences remove a and slope has units of y divided by units of x. A nonzero intercept can represent a real initial value or a systematic offset; context decides.

A proposed model should be tested by residuals or comparisons across the range, not by one matching point. An outlier warrants a recorded reason and, if possible, a repeat. Deleting it just to improve agreement is not evidence.

Change one cause; measure one response

Name the independent variable you change and the dependent variable you measure. Hold relevant conditions constant, use a suitable comparison or control and include repeats. Randomising order can reduce confounding by gradual temperature drift or instrument changes.

A conclusion should state its range and limitations. Interpolation uses the measured range; extrapolation extends beyond it and may fail when conditions change. An overlap of uncertainty intervals alone is not a full statistical test, but it can warn that an apparent difference is not resolved by the stated measurements.

0123456789102.0 ± 0.1 cm7.0 ± 0.1 cmDifference: 5.0 ± 0.2 cm (worst-case bound)
The central endpoint difference is 5.0 cm. With stated bounds of ±0.1 cm at each end, the worst-case length spans 4.8 to 5.2 cm. A shared offset could behave differently.

Rules and when they apply

Mean=sum of readingsnumber of readings\text{Mean}=\frac{\text{sum of readings}}{\text{number of readings}}
A summary of repeated values; report units and an appropriate precision.

Repeated measurements of a comparable quantity, with any exclusions justified.

Slope=ΔyΔx\text{Slope}=\frac{\Delta y}{\Delta x}
Use separated points on a justified line/model and retain units.

A constant slope is meaningful only if the assumed linear relation fits the range.

Worst-case uncertainty of a difference = sum of absolute input bounds
If readings are each within stated ± bounds, opposite errors can add in a subtraction.

This is a conservative bound, not a standard deviation or a statistical confidence interval.

Follow the reasoning

Worked example 1

Subtract two uncertain readings

A ruler reading at one end is 2.0 ± 0.1 cm and the other is 7.0 ± 0.1 cm. Estimate the length and its worst-case uncertainty.

Step-by-step explanation
  1. Central length is 7.0 − 2.0 = 5.0 cm.
  2. The smallest possible length is 6.9 − 2.1 = 4.8 cm; the largest is 7.1 − 1.9 = 5.2 cm.
  3. The half-width is 0.2 cm, equal to the sum of the two absolute bounds.

5.0 ± 0.2 cm as a worst-case bound.

Check: Subtracting the two uncertainties would wrongly suggest perfect precision.

Worked example 2

Find what an offset cannot change

An ammeter reads 0.10 A too high at every setting. Voltage is correct. Does the slope of V vertically against recorded I horizontally change? Assume a truly ohmic, constant-temperature resistor.

Step-by-step explanation
  1. Let recorded current be ImI_{\mathrm m} = I + 0.10 A. Then V = RI = R(ImI_{\mathrm m} − 0.10 A).
  2. This is a straight line with slope R and a shifted intercept −0.10R V.
  3. Current differences are unchanged, so resistance inferred from the slope remains correct under this offset-only model.

The slope is unchanged; the intercept shifts.

Check: Using a single ratio V/ImI_{\mathrm m} instead of a slope would give a biased resistance.

Mistakes worth catching

“Repeating a biased instrument fixes its calibration.”

Repeats assess variation; a constant offset requires a calibration or reference comparison.

“More decimal places mean more accurate.”

Extra digits may exceed the instrument’s useful resolution and do not remove bias or experimental limitations.

Quick revision checklist
  • State a prediction and the variables.
  • Record units, controls, repeats and instrument limits.
  • Inspect slope, intercept and deviations; distinguish bounds from statistical claims.

Try it without the worked example

Ten separately written questions. Your answers are saved on this browser; finish to see the score and explanations.

Take the topic test →